Properties:
KR-0100 is a high-effective scale inhibitor, it is suitable for reverse osmose (RO), nanofiltration (NF) and ultrafiltration (UF) system. KR-0100 can inhibit the scale deposit on membrane surface, improve water quality, lower operation expanse. This product has the following properties:
(1). Inhibit inorganic scale formation for a wide concentration span, the largest permitted LSI value is 2.8 when no acid is added.
(2). Not flocculate with ferric oxide, aluminia oxide or silica oxide to form suspended substance;
(3). Inhibit the pollution from ferric, aluminium or heavy metals pollutants. The permitted ferric concentration for inlet water supply can reach to 8.0ppm.
(4). Inhibit the flocculate and deposit of silica, the permitted silica concentration for condense side can reach to 290ppm.
(5). Be used in CA, TFC, NF and UF membranes for RO system.
(6). Good solubility and stability.
(7). Effective in pH 5-10.
Specification:
Items | Index | |
---|---|---|
Appearance | Clear liquid | Clear transparent liquid |
pH(1% water solution) | 2.0±0.5 | 2.0-3.0 |
Density (20℃), g/cm3 | 1.03-1.06 | 1.45±0.05 |
Main content | Micromolecular containing P | Micromolecular containing P |
Decomposition product under high temperature | orthophosphate | orthophosphate |
Package and Storage:
200L plastic drum,IBC(1000L),customers’ requirement.
Protective measures for KR-0100:
Here are some general protective measures that should be followed:
- Personal Protective Equipment (PPE): Always wear appropriate PPE, including gloves, goggles or face shield, and protective clothing when handling any chemical. Follow the manufacturer’s instructions for recommended PPE.
- Engineering Controls: Ensure proper ventilation in the working area to minimize exposure to chemical vapors. Use local exhaust ventilation systems or work in well-ventilated areas.
- Storage and Handling: Store the chemical in a cool, dry, and well-ventilated area, following proper storage procedures outlined by the manufacturer. Keep it away from heat, ignition sources, and incompatible materials.
- Spill Management: In case of a spill, contain the area and prevent the chemical from entering drains, sewers, or water bodies. Absorb spills with appropriate absorbent materials and dispose of them according to local regulations.
- Handling Precautions: Avoid direct contact with the chemical. If contact occurs, immediately wash the affected area with soap and water. Avoid inhaling chemical vapors or mist. If respiratory irritation occurs, move to fresh air immediately.
- Training and Education: Provide adequate training to employees on safe handling, storage, and disposal of chemicals. Ensure they are aware of the potential hazards and know how to respond in case of an emergency.
- Follow Regulations: Comply with all applicable local, national, and international regulations regarding the use, transportation, and disposal of chemicals. Stay updated on any changes in regulations or safety guidelines.